1.Starting voltage:the voltage at which the DC fan can be started after the switch " ON" is turned on

2.Locking current:the fan that can lock the machine.Locking current is measured in fresh air for 3 minutes

3.Noise standard:The noise standard test is carried out according to DIN 45635 standard, and the measurement is carried out in a sound insulation room, with the microphone placed at one meter of the DC fan

4.Air flow data and pressure data are determined according to " AMCA Standard" or DIN 24163 Rules.The data measurement is performed in a double pressure chamber and

It is necessary to measure the pressure data on each side of the pressure chamber.

5.Speed:The speed is measured after 3 minutes of continuous rotation

6.Current:The current is measured after 3 minutes of continuous rotation

7.Input power:The input power is measured after 3 minutes of continuous rotation.


?